Publications

Showing 123 results for Author: Theodore M. Biewer

  • Nov, 2023

    Conference Paper

    Fast visible cameras and a filterscope are used to examine the visible light emission from Oak Ridge National Laboratory’s Proto-MPEX. The filterscope has been configured to perform helium line ratio measurements using emission lines at 667.9, 728.1, and 706.5 nm. The measured lines should be mathematically inverted and the ratios compared to a collisional radiative model…

  • Nov, 2023

    Conference Paper

    Proto-MPEX is a linear plasma device being used to study a novel RF source concept for the planned Material Plasma Exposure eXperiment (MPEX), which will address plasma-materials interaction (PMI) for nuclear fusion reactors. Plasmas are produced using a large diameter helicon source operating at a frequency of 13.56 MHz at power levels up to 120 kW. In recent experiments…

  • Nov, 2023

    Journal

    Laser-induced breakdown spectroscopy (LIBS) results are presented that provide depth-resolved identification of He implanted in polycrystalline tungsten (PC-W) targets by a 200 keV He+ ion beam, with a surface temperature of approximately 900 °C and a peak fluence of 1023 m−2. He retention, and the influence of He on deuterium and tritium recycling, permeation, and retenti…

  • Nov, 2023

    Conference Paper

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of…

  • Nov, 2023

    Journal

    The physics of electron and ion heating of high-density deuterium helicon plasmas (>3 × 1019 m−3) in the Proto-Material Plasma Exposure Experiment linear device are under investigation. Theoretical estimates indicate that for efficient heating, discharges with very low neutral gas content (≪0.1 Pa) in the heating sections are required to minimize collisional losses and cha…

  • Nov, 2023

    Conference Paper

    The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device to test the plasma source concepts for the future Material Plasma Exposure eXperiment (MPEX). MPEX is planned to address plasma material interactions under fusion reactor divertor conditions as will occur in devices like DEMO, including the plasma exposure of a-priori neutron irradiate…

  • Nov, 2023

    Journal

    The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) linear plasma device is a test bed for exploring and developing plasma source concepts to be employed in the future steady-state linear device Material Plasma Exposure eXperiment (MPEX) that will study plasma-material interactions for the nuclear fusion program. The concept foresees using a helicon plasma sourc…

  • Nov, 2023

    Journal

    The ITER divertor will have to handle the boundary plasma power exhaust in the form of high heat and particle flux. The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a plasma source development device for the proposed Material Plasma Exposure eXperiment (MPEX), which is intended to create fusion reactor divertor-like plasma conditions for studying plasma ma…

  • Nov, 2023

    Journal

    Plasma material interaction (PMI) studies are crucial to the successful development of future fusion reactors. Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a prototype design for the MPEX, a steady-state linear device being developed to study PMI. The primary purpose of Proto-MPEX is developing the plasma heating source concepts for MPEX. A power accountin…

  • Nov, 2023

    Journal

    The Prototype Material Plasma Exposure Experiment at the Oak Ridge National Laboratory utilizes a variety of power systems to generate and deliver a high heat flux plasma onto the surface of material targets. In the experiments described here, a deuterium plasma is produced via a ∼100 kW, 13.56 MHz RF helicon source, to which ∼20 kW of 28 GHz microwave power is applied. Th…

1
2
3
4
…
11