- By:
- Raftery, Alicia M; Jellison Jr, Gerald E; Cureton, William F; Adorno Lopes, Denise ; Kim, Howard T; Brown, Daniel R
- Journal Name:
- Journal of Nuclear Materials
- Page Number:
- 156934
- Volume:
- 632
- Publication Date:
- August 19, 2026
- View DOI Listing:
- https://doi.org/10.1016/j.jnucmat.2026.156934
Abstract
The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.